Search results for "Mr angiography"

showing 6 items of 6 documents

MR-Angiographie peripherer Gefäße mit automatischer Verschiebetisch-Technik bei 1.0 T im Vergleich zur i. a. DSA

1999

PURPOSE Contrast-enhanced (CE) 3D-MR angiography of peripheral arteries was performed in 8 patients with peripheral arterial occlusive disease by applying a new tracking technique on a 1.0 T system (Magnetom Harmony, Siemens). The studies were compared with intra-arterial digital angiography as gold standard. MATERIALS AND METHODS Imaging of the distal aorta, pelvis, upper and lower limb arteries was accomplished with a Flash-3D-sequence (TR/TE = 6.2/3.2 ms) within 26 s acquisition time of each region after a single bolus of 30 ml contrast agent. Individual circulation time was determined by a test bolus before each examination. RESULTS 112 vessel segments were evaluated. MR angiography ach…

Aortamedicine.medical_specialtymedicine.diagnostic_testbusiness.industryVascular diseaseMr angiographyGold standard (test)medicine.diseasePeripheralStenosismedicine.anatomical_structuremedicine.arteryAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessArteryRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

The effects of linearly increasing flip angles on 3D inflow MR angiography

1994

As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…

Materials scienceInflowsymbols.namesakeNuclear magnetic resonanceHumansPopliteal ArteryRadiology Nuclear Medicine and imagingSaturation (magnetic)Fourier AnalysisModels CardiovascularMr angiographyReproducibility of ResultsPulse durationRangingArteriesImage EnhancementMagnetic Resonance ImagingComputational physicsTibial ArteriesFourier transformFibulaRegional Blood FlowBlood CirculationsymbolsSlabBlood VesselsArtifactsAlgorithmsBlood Flow VelocityExcitationMagnetic Resonance in Medicine
researchProduct

Depiction of anomalous coronary vessels and their relation to the great arteries by magnetic resonance angiography

2000

Three-dimensional respiratory-gated coronary MR angiography (MRA) allowed accurate analysis of the anatomy of the coronary arteries and their relation to the adjacent anatomic structures in two patients with anomalous origin and proximal course of the coronary vessels. Together with functional tests, it decisively influenced further therapy.

Malemedicine.medical_specialtymedicine.diagnostic_testbusiness.industryCoronary Vessel AnomaliesMr angiographyInterventional radiologyGeneral MedicineMiddle AgedCoronary VesselsMagnetic resonance angiographyCoronary arteriesImaging Three-Dimensionalmedicine.anatomical_structureGreat arteriesHumansMedicineFemaleRadiology Nuclear Medicine and imagingRadiologybusinessAortaMagnetic Resonance AngiographyNeuroradiologyEuropean Radiology
researchProduct

Ventrolateral Compression of the Brain Stem in Essential Hypertension: MR Angiography Study

1997

Our purpose was to evaluate neurovascular compression at the level of ventrolateral medulla and NVC with the IXth and the Xth cranial nerves in patients with essential hypertension and in healthy volunteers using high resoluted Spoiled Recalled Gradient Echo (SPGR) sequences, allowing the detection of stationary tissues and moving spins. Thirty patients (19 men and 11 women) with essential hypertension were examined. Patient's ages ranged from 24 to 64 years-old (mean age was 48 y.o.). Patients older than 65 were excluded. The average of systolic blood-pressure of hypertensive patients was 183 ± 10 mmHg, while the diastolic pressure was 98 ± 10.5 mmHg. In conclusion, we consider axial sing…

medicine.medical_specialtyRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryCranial nervesMr angiographyEssential hypertensionmedicine.diseaseMagnetic resonance angiographySurgeryBlood pressureInternal medicineCardiologyMedicineRadiology Nuclear Medicine and imagingIn patientNeurology (clinical)businessMedullaGradient echoRivista di Neuroradiologia
researchProduct

Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial

2007

OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…

AdultMalemedicine.medical_specialtyContrast MediaLumen (anatomy)Arterial Occlusive DiseasesArterial Occlusive Diseases/*diagnosis Contrast Media Image Enhancement/*methods Magnetic Resonance Angiography/*methods Meglumine/*analogs & derivatives/therapeutic useSensitivity and SpecificityMegluminecontrast agents; diagnostic performance; gadobenate dimeglumine; MR angiography; peripheral arterial occlusive diseasediagnostic performancePeripheral arterial occlusive diseaseMulticenter trialOrganometallic CompoundsHumansMedicineRadiology Nuclear Medicine and imagingcontrast agentsGADOBENATE DIMEGLUMINEAgedPeripheral Vascular DiseasesMR angiographymedicine.diagnostic_testbusiness.industryVascular diseaseMr angiographyReproducibility of ResultsGeneral MedicineDigital subtraction angiographyMiddle AgedSouth Americacontrast agentImage Enhancementmedicine.diseaseEuropemedicine.anatomical_structureThighFemaleRadiologybusinessperipheral arterial occlusive diseaseMagnetic Resonance AngiographyArterygadobenate dimeglumine
researchProduct

MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarte…

2007

Purpose To compare gadobenate dimeglumine (Gd-BOPTA)–enhanced MR angiography (i.e., contrast-enhanced MRA [CE-MRA]) of the pedal vasculature with selective digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). Materials and Methods A total of 22 patients with PAOD were prospectively examined at 1.5T. For contrast enhancement, 0.1 mmol/kg body weight of Gd-BOPTA were applied. MRA consisted of dynamic imaging with acquisition of six consecutive data sets. Acquisition time for each data set was 24 seconds, voxel size was 1.0 × 1.0 × 1.3 mm3. A total of 20 out of 22 patient underwent selective DSA, two patients fine-needle DSA. DSA and MRA were per…

AdultMalemedicine.medical_specialtyImage qualitymedia_common.quotation_subjectDynamic imagingContrast MediaArterial Occlusive DiseasesMegluminemedicineOrganometallic CompoundsContrast (vision)HumansRadiology Nuclear Medicine and imagingIn patientcardiovascular diseasesProspective StudiesGADOBENATE DIMEGLUMINEVascular Patencymedia_commonAgedAged 80 and overPeripheral Vascular Diseasesmedicine.diagnostic_testbusiness.industryFootMr angiographyAngiography Digital SubtractionDigital subtraction angiographyMiddle Agedmedicine.diseasebody regionsStenosiscardiovascular systemFemaleRadiologyNuclear medicinebusinessMagnetic Resonance Angiographycirculatory and respiratory physiologyJournal of magnetic resonance imaging : JMRI
researchProduct